Wrapper for measured values. More...
#include <sen5x.h>
Data Fields | |
| uint16_t | mass_concentration_pm1p0 | 
| raw value is scaled with factor 10: PM1.0 [µg/m³] = value / 10  | |
| uint16_t | mass_concentration_pm2p5 | 
| raw value is scaled with factor 10: PM2.5 [µg/m³] = value / 10  | |
| uint16_t | mass_concentration_pm4p0 | 
| raw value is scaled with factor 10: PM4.0 [µg/m³] = value / 10  | |
| uint16_t | mass_concentration_pm10p0 | 
| raw value is scaled with factor 10: PM10.0 [µg/m³] = value / 10  | |
| uint16_t | number_concentration_pm0p5 | 
| raw value is scaled with factor 10: PM0.5 [#/cm³] = value / 10  | |
| uint16_t | number_concentration_pm1p0 | 
| raw value is scaled with factor 10: PM1.0 [#/cm³] = value / 10  | |
| uint16_t | number_concentration_pm2p5 | 
| raw value is scaled with factor 10: PM2.5 [#/cm³] = value / 10  | |
| uint16_t | number_concentration_pm4p0 | 
| raw value is scaled with factor 10: PM4.0 [#/cm³] = value / 10  | |
| uint16_t | number_concentration_pm10p0 | 
| raw value is scaled with factor 10: PM10.0 [#/cm³] = value / 10  | |
| uint16_t | typical_particle_size | 
| raw value is scaled with factor 1000: Size [µm] = value / 1000  | |
| int16_t | ambient_humidity | 
| raw value is scaled with factor 100: RH [%] = value / 100  | |
| int16_t | ambient_temperature | 
| raw value is scaled with factor 200: T [°C] = value / 200  | |
| int16_t | voc_index | 
| raw value is scaled with factor 10: VOC Index = value / 10  | |
| int16_t | nox_index | 
| raw value is scaled with factor 10: NOx Index = value / 10  | |